THE FASNSEAL VENT KIT IS

DESIgNED FOR SIDEWALL

VENTINg OF INSTANTANEOUS

TANKLESS WATER HEATERS AND

WALL HUNg BOILERS.

This kit contains three easy to install parts

that provide the ability to vent through any

combustible wall. The Vent Kit is compatible

with standard FasNSeal® (FNS) products.

Be sure to read these instructions completely,

and those of the appliance itself, before

proceeding with the installation of this kit.

Local codes and regulations may be

applicable and should always be adhered to.

Proper joint assembly is essential for a safe

installation.

Failure to follow these instructions and good

sound installation practices can lead to risk of

pipe breakage, fire and carbon

monoxide poisoning.

KIT COMPONENTS:

The following items are included in the box

for this kit:

• Wall thimble termination

• Telescoping 90-degree elbow

• 12-inch long appliance adapter for the

FSWMK4 or a 12-inch standard vent length

for the FSWMKB3

• Installation Instructions

gENERAL REQUIREMENTS

1" CLEARANCE TO COMBUSTIBLES

3" MINIMUM

1"

MIN

Figure 17

IMPORTANT

Failure to conform to any of these

requirements may violate local, state, or

national codes and create conditions that

may cause catastrophic property damage

or personal injury.

• Proper operation of the vent system and

appliance depends on the use and correct

assembly of all parts specified by M&G

DuraVent., Inc.. for a particular installation.

• If required by the appliance manufacturer,

a drain fitting must be located as close as

possible to the appliance flue outlet.

• More than one appliance may not be

connected into the same vent kit termination.

• FNS must avoid any contact with plumbing

or electrical systems.