Instructions, Fasnseal flex terminations, 15 figure 16 – DuraVent FasNSeal Single-Wall User Manual

Page 15: Figure 15

Advertising
background image

15

Figure 16

TOP PLATE

SEALANT

ExISTING

MASONRy

CHIMNEy

Figure 15

INSTRUCTIONS

1. If a tee is needed lower down the liner as in

Step 3 of the previous section to the proper

location, even with the opening in

the chimney.

2. Attach the appropriate drain fitting to the

bottom of the Tee Body.

3. Be sure to remember to connect the

condensate drain at the bottom of the stack.

See previous section on Condensate Drains

for instructions.

FASNSEAL FLEx TERMINATIONS

For the standard vertical termination

installations see previous section vertical,

through the roof installation or follow

steps below.

1. Slide the Top Plate over the Flex Liner and

seal the Top Plate to the masonry chimney

using a bead of non-hardening sealant

around the top of the chimney and underside

of the Top Plate (Figure 15).

2. Leave at least 4 additional inches of

FasNSeal Flex to allow the Rain Cap to

sufficiently grab the liner.

3. Slip the Storm Collar portion of the Rain

Cap over the liner, position it over the Top

Plate and tighten draw band. Reassemble

Rain Cap (Figure 16).

RAIN CAP

STORM

COLLAR

TOP

PLATE

Advertising