Quest 105, 155, and 205 Dual

Installation, Operation and Maintenance Instructions

6

www.QuestProtect.com

[email protected]

4.1B Ducted Return and Supply (fig. 2)

Dehumidification performance can be modified by adding an return and/or supply duct to circulate air.
For optimal drying, use return duct to draw warm, moist air from near the ceiling.

4.1C Remote Area, w/ Ducted Supply (fig. 3)

A simplified remote installation method than above uses ducting between the Quest Dual discharge and the
humid room; the Quest Dual inlet draws air from the room in which it’s located. This works well if there is
an adequate air flow path between the two rooms; e.g. high door undercut, louvered door or wall grill. This
eliminates the need to remote mount the humidity control.

Input of

Humid Air

Front View

Output of Dehumidified Air

Front View

CONDITIONED SPACE

Input of

Humid Air

Output of Dehumidified Air

Advertising