Fixing the installation plate, Connecting the assembly cable, Cable specification connecting the cable – Sunlight Supply Samsung Linesets for Mini Split Systems User Manual

Page 28

Advertising
background image

28

Fixing the installation plate

Wall

<0.79inch

(20mm)

Plastic

Anchor

2. Fix the indoor unit.
If you fix the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

If you fix the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be

attached to the window frame.

(2) Attach the wooden uprights to the window frame giving

attention to the weight of the indoor unit.

(3) Attach the installation plate to the wooden upright using

tapping screws.

If you fix the indoor unit on a gypsum board
(1) Use stud finder to find out locations of the studs.
(2) Fix the plate hanger on two studs.

• If you mount the plate to a concrete wall using plastic anchors, make sure that

gaps between the wall and the plate, created by projected anchor, is less than

0.79inch(20mm).

• Search for other spots if there are less than two studs, or the distance between the studs are different from the

plate hanger.

• Fix the installation plate without inclining to one side.

• Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not

strong enough to withstand the product weight, the unit could fall and cause injury.

Connecting the assembly cable

• Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect to the

power supply, it must be incorporated in a wire with a contact opening of ≥0.118inch(3mm).

Cable specification

Connecting the cable

Electrical work
(1) For electrical and earth works, comply with the ‘technical standards of electrical installations’ and the the ‘wiring

regulations’ of the Electricity Enterprises Act.

(2) Tighten the terminal block screw to under 0.87ft

lb(12kgf

cm).

(3) Precautions when connecting terminal blocks of the indoor unit

Before connecting, make sure the connecting part of the terminal socket is facing upwards.

Upside down

The terminal

socketis damaged.

There is no ring

terminalto cover the wire.

Model

Use

AWG

Cross sectional area (mm

2

)



09/12/18/24

Main power supply 3-wire Power cable

13 or fewer

2.5 or more

Indoor power supply 3-wire power cable

15 or fewer

1.5 or more

2-wire assembly cable

15 or fewer

1.5 or more



36

Main power supply 3-wire Power cable

10 or fewer

4 or more

Indoor power supply 3-wire power cable

15 or fewer

1.5 or more

2-wire assembly cable

15 or fewer

1.5 or more

Vivaldi MAX_AQN09VFU@@ IB&IM_32163A_E.indd 28

2012-6-20 13:28:57