2 . Open the front grille.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.

(Refer to the picture below)

5 . Pass the other end of the cable through the 2.56inch(65mm) hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the front grille.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.

• Each wire is labeled with the corresponding terminal number.

1. Extend the assembly cable if necessary.

• Do not connect two or more different cables to extend the length.

It may cause fire.

When you install the unit, make first refrigerant connections and then electrical connections.

Connect the air conditioner to grounding system before performing the electrical connection.

If unit is uninstalled, first disconnect electrical cables, then refrigerant connections.

A 24.6ft(7.5m) pipe is supplied with the air conditioner. If the outdoor unit is more than 24.6ft(7.5m) away from the indoor

unit,you must extend the cable. The maximum length of the cable is 15(09/12)/20(18/24/36) meters.

• Each wire is labeled with the corresponding terminal number.

Indoor unit

Outdoor unit

There must be no space between the terminal and the screw when connected.

- Any remaining space may become a fire hazard due to overheating of the electrical contact.

The terminal socket

is upside down.

Either the screw is not fitted properly

or there is a space between the screw

and the ring terminal.

• For the terminal block wiring, use a wire with a ring terminal socket only.

Regular wires without a ring terminal socket may become a fire hazard due to overheating

of the electrical contact during a wiring work.

Indoor unit

Outdoor unit

The appearance of the unit may be different from the diagram depending on the model.

L1 L2

L1 L2

F1 F2

F1 F2

L1 L2

F1 F2



09/12/18/24



36

L3 L4

L3 L4

F1 F2

L3 L4

F1 F2

L1 L2

F1 F2

Indoor unit

Outdoor unit

Vivaldi MAX_AQN09VFU@@ IB&IM_32163A_E.indd 29