Installing and connecting the drain hose of the indoor unit

• The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page

39 for further details.

• Make sure the installed direction of the drain hose is correct.

Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the

furniture or floors.

• DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

• Make sure the indoor unit is in upright position when you pour water to check for leakage.

Make sure that the water does not overflow onto the electrical part.

Change the direction only when it is necessary.
1. Detach the rubber cap with the plier.

2. Detach the drain hose by pulling it and turning to the left.

3. Insert the drain hose by fixing it with the screw into the groove of the drain

hose and the outlet of the drain pan.

4. Attach the rubber cap with a screwdriver by turning it to the right until it

fixes to the end of the groove.

5. Check for leakage on both side of the drain outlet.

Changing direction of the drain hose

Drain hose

Screw hole

Screw

Rubber cap

Drain pan outlet

Pour the water in direction of arrow.

Direction of the drained water