Lenovo ThinkServer TD200 User Manual

Page 11

Advertising
background image

Table 1. Comparison of the IMM features and combined BMC and Remote Supervisor Adapter II features in
ThinkServer servers (continued)

Description

BMC with Remote Supervisor Adapter II

(TS100, TS100, TS100x, RS110, and RD120)

IMM(RD210, RD220, and later)

Error logging

The BMC provides a BMC system-event log
(IPMI event log).

The Remote Supervisor Adapter II provides a
text-based log that includes descriptions of
events that are reported by the BMC. This log
also contains any information or events
detected by the Remote Supervisor Adapter II
itself.

The IMM has two event logs:

1.

The system-event log is available
through the IPMI interface.

2.

The chassis-event log is available
through the other IMM interfaces. The
chassis-event log displays text messages
that are generated using the Distributed
Management Task Force specifications
DSP0244 and DSP8007.

Note:

For an explanation of a specific event

or message, see the Hardware Maintenance
Manual
that is available on the Lenovo
Support Web site at http://
www.lenovo.com/support.

Monitoring

The BMC with Remote Supervisor Adapter II
has the following monitoring capabilities:

v

Monitoring of server and battery voltage,
server temperature, fans, power supplies,
and processor and DIMM status

v

Fan speed control

v

Hardware Failure Prediction

v

System diagnostic LED control (power,
hard disk drive, activity, alerts, heartbeat)

v

Automatic Server Restart (ASR)

v

Automatic BIOS Recovery (ABR)

The IMM provides the same monitoring
capabilities as the BMC and Remote
Supervisor Adapter II. When used in a
RAID configuration, expanded hard disk
drive status, including disk drive Hardware
Failure Prediction, is supported by the IMM.

Chapter 1. Introduction

5

Advertising
This manual is related to the following products: