Configuring global remote alert settings – Lenovo ThinkServer TD200 User Manual

Page 31

Advertising
background image

2.

In the navigation pane, click Alerts. The Remote Alert Recipients page is
displayed. You can see the notification method and alert status for each
recipient, if they are set.

3.

Click one of the remote alert recipient links or click Add Recipient. An
individual recipient window opens.

4.

In the Status field, click Enabled to activate the remote alert recipient.

5.

In the Name field, type the name of the recipient or other identifier. The name
that you type appears as the link for the recipient on the Alerts page.

6.

In the E-mail address field, enter the alert recipient's e-mail address.

7.

Use the check box to include event logs with e-mail alerts.

8.

In the Monitored Alerts field, select the type of alerts that are sent to the alert
recipient.
The remote alerts are categorized by the following levels of severity:

Critical alerts

Critical alerts are generated for events that signal that a server
component is no longer functioning.

Warning alerts

Warning alerts are generated for events that might progress to a critical
level.

System alerts

System alerts are generated for events that occur as a result of system
errors or for events that occur as a result of configuration changes.

All alerts are stored in the event log and sent to all configured remote alert
recipients.

9.

Click Save.

Configuring global remote alert settings

The global remote alert settings apply only to forwarded alerts.

Complete the following steps to set the number of times that the IMM attempts to
send an alert:
1.

Log in to the IMM on which you want to set remote alert attempts. For more
information, see Chapter 2, “Opening and using the IMM Web interface,” on
page 9.

2.

In the navigation pane, click Alerts and scroll down to the Global Remote
Alert Settings

area.

Use these settings to define the number of remote alert attempts and the length
of time between the attempts. The settings apply to all configured remote alert
recipients.

Remote alert retry limit

Use the Remote alert retry limit field to specify the number of
additional times that the IMM attempts to send an alert to a recipient.
The IMM does not send multiple alerts; additional alert attempts occur
only if there is a failure when the IMM attempts to send the initial
alert.

Note:

This alert setting does not apply to SNMP alerts.

Chapter 3. Configuring the IMM

25

Advertising
This manual is related to the following products: