Volts command, Description, Example – Lenovo ThinkServer TD200 User Manual

Page 86: Vpd command, Syntax

Advertising
background image

CPU2

58/14

72/22

80/27

85/29

9/320

DASD1

66/19

73/23

82/28

88/31

9/332

Amb

59/15

70/21

83/28

90/32

9/355

system>

Notes:

1.

The output has the following column headings:

WR: warning reset
W: warning
T: temperature (current value)
SS: soft shutdown
HS: hard shutdown

2.

All temperature values are in degrees Fahrenheit/Celsius.

volts command

Description

Use the volts command to display all the voltages and voltage thresholds. The
same set of voltages are displayed as in the Web interface.

Example

system> volts

HSL

SSL

WL

WRL

V

WRH

WH

SSH

HSH

----------------------------------------------------------
5v

5.02

4.00

4.15

4.50

4.60

5.25

5.50

5.75

6.00

3.3v

3.35

2.80

2.95

3.05

3.10

3.50

3.65

3.70

3.85

12v

12.25 11.10 11.30 11.50 11.85 12.15 12.25 12.40 12.65

-5v

-5.10 -5.85 -5.65 -5.40 -5.20 -4.85 -4.65 -4.40 -4.20

-3.3v -3.35 -4.10 -3.95 -3.65 -3.50 -3.10 -2.95 -2.80 -2.70
VRM1

3.45

VRM2

5.45

system>

Note:

The output has the following column headings:

HSL: hard shutdown low
SSL: soft shutdown low
WL: warning low
WRL: warning reset low
V: voltage (current value)
WRH: warning reset high
WH: warning high
SSH: soft shutdown high
HSH: hard shutdown high

vpd command

Syntax

vpd sys
vpd IMM
vpd biosvpd dsa

Description

Use the vpd command to display vital product data for the system (sys), IMM,
server firmware (bios), and Dynamic System Analysis Preboot (dsa). The same
information is displayed as in the Web interface.

80

Integrated Management Module: User Guide

Advertising