Konica Minolta Darwin VDP Software User Manual

Page 40

Advertising
background image



Page 40 of 92

T EC - I T B a r c o d e So f t w a re R e f e re n c e

6.1.60 Pharmacode Two-Track

Symbology number:

53

Valid characters:

numeric [0..9] and generic;

Quiet zone:

left/right: 6 mm

Module width:

--

Standard print ratio:

1:1

Ratio format:

1B:1S

Default check digit:

None (eCDNone)

Symbol size:

see Notes

This code was invented and specified by Laetus

®

. Pharmacode assigns numeric values to the bars.

It is used for medicine packing in pharmaceutically area; for small labels. Usually Pharmacode is
printed without a human readable text.

The dimensions are:

2-track bar width: 1 mm

space bars: 1 mm

bar height above/below: 4-6 mm

height of the long bar: 8-12 mm

It offers a high printing tolerance and is readable very fast (200 readings per second).

6.1.61 Pharma Zentralnummer (PZN)

Symbology number:

52

Valid characters:

“0”..”9”, 6 digits + 1 check digit

Quiet zone:

see Code 39

Module width:

see Code 39

Standard print ratio:

see Code 39

Ratio format:

see Code 39

Default check digit:

PZN check digit (eCDPZN)

Possible check digits:

User supplied

Symbol size:

see Code 39

PZN -1234562

PZN uses Code 39 as the base symbology. It uses a special check digit and the human readable
text always contains

the prefix “PZN-“ (which is not encoded in the barcode data).

6.1.62 Planet 12

Symbology number:

82

Valid characters:

“0”..”9”, 11 digits + 1 check digit

Quiet zone:

left/right: 1/25 inch
top/bottom: 1/8 inch

Module width:

--

Standard print ratio:

1:1

Ratio format:

1B:1S

Default check digit:

Modulo 10 Planet (eCDMod10Pla)

Possible check digits:

User supplied

Symbol size:

11 digits + 1 check digit

123456789014

This code was developed for the United States Postal Services. It is a 3-of-5 variant of the Postnet
barcode.

Advertising