T EC - I T B a r c o d e So f t w a re R e f e re n c e

The values for the properties postal code, country code, service class, preamble and date are
extracted from the barcode data (

Text

property). If this data values are encoded in the text string the

values of the belonging properties are overdriven.

The

Format

property of

TBarCode

must be set to "S" (switches extracting of SCM Data to “on”).

And the property

EscapeSequences

must be switched on.

The

Text

property should contain the whole text according to UPS standard including preamble,

date, postal code, country code and service class. Special characters and separators must be
replaced by escape sequences Rs, Gs, Eot (also refer to Escape Sequences):

Figure 1: MaxiCode UPS Encoding

6.2.5

MicroPDF417

Symbology number:

84

Valid characters:

Alphanumeric and/or bytes

Quiet zone:

left/right: 1X

Module width:

--

Print ratio:

1:2:3:4:5:6:1:2:3:4:5:6

Ratio format:

1B:2B:3B:4B:5B:6B:1S:2S:3S:4S:5S:6S

Default check digit:

Automatic (symbology specific).

Size:

--

TBarCode/X control sequence

For V1.x:

$_tbcs b84 dThis is a MicroPDF417$_tbce

For V2.x:

$_tbcs -b84

–d"This is a MicroPDF417"$_tbce

This stacked 2D symbology is used to encode large quantities of data.