37 inspection and service – Bosch 25/32kW User Manual

Page 38

Advertising
background image

INSPECTION AND SERVICE

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32

8 716 113 389b (09/07)

37

INSPECTION AND SERVICE

CAUTION: ISOLATE THE WATER,
ELECTRICITY AND OIL MAINS SUPPLIES
BEFORE STARTING ANY WORK AND
OBSERVE ALL RELEVANT SAFETY
PRECAUTIONS.

DO NOT USE PRESSURE WASHERS OR
STEAM CLEANERS ON THIS APPLIANCE
OR ITS CABINET.

WARNING: EXTERNAL EQUIPMENT
OPERATED AT 230 VOLTS SHOULD NOT
BE SERVICED OR REPAIRED UNDER
ADVERSE WEATHER CONDITIONS

Routine servicing:

To maintain efficient boiler operation, the
following should be carried out at least once a
year:

Carry out a pre-service check and note any

operational faults:

Pre-Service Check:

1

Unndo the screws at the base of the

front panel using the tool provided and pull
the panel down and out to remove.
Store safely away from the working area.

Operate the appliance and system and note any
faults which may need to be corrected during
the service.

Switch into service mode at switch (A).

2

Depress locking ears and unplug burner

lead (B) from control box (C).

• An adapter lead is available to allow mains

voltage service aids to be operated from
the service connection (G). (Service lead
Part No. 8 716 113 483 0).

3

Loosen clip (D) to detach air duct.

4

Unscrew burner retainers (E) to release

the burner combustion head (F).

Lift burner away, taking care not to over

strain the flexible oil hose/s or
connections.

See the following instructions for detail of some
of the service requirements listed
below:

Check and clean the burner.

Replace burner nozzle and flexible oil

hose/s.

Check and clean the baffle retainers.
Check and clean the baffles.
Check and clean the heat exchangers

surfaces.

Check the combustion chamber access

door insulation board.
Check that the flue system is unobstructed
and clean as necessary.

Clean or replace all oil filters.

Check that the condensate system is not

obstructed, clean and refill the condensate
trap as necessary.

Sealed systems only: The PRV is a safety

device and must be checked for correct
operation.
The expansion vessel pressure must be
checked and adjusted as required.

on

service

F

D

3

E

4

1

A

C

B

2

G

SER

V

IC

IN

G

&

SP

A

RES

Advertising
This manual is related to the following products: