INSPECTION AND SERVICE

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32
8 716 113 389b (09/07)

40

SER

V

IC

IN

G

&

SP

A

RES

INSPECTION AND SERVICE

Re-commission the burner:

1

Align burner combustion head (A) into the

boiler housing tube with gasket (B)
correctly fitted.

Push firmly down to compress the gasket (B).
Tighten burner retainers (C) sufficiently to

ensure a good seal.

IMPORTANT:
Ensure the gasket is a good seal between
the burner combustion head and the boiler
housing to prevent flue gases escaping.

Refit flexible air duct and secure with clip (D).

2

Plug burner lead (E) into control box (F).

Connect an oil pressure gauge to the oil

pump, run the burner and check the oil
pressure is correct for the required boiler
output. Check that the smoke reading is
between 0 and 1, if the smoke reading is
above 1 check the air setting. If the air
setting is correct check that the burner has
been reassembled correctly.

Allow the boiler to warm up then check the
combustion settings are correct as
indicated in the table below, adjust the
CO

2

if necessary using the air shutter.

When the combustion is correct turn off the
boiler, remove the pressure gauge and refit
the blanking plug and plastic cover.

Refit panels:

3

Refit the top panel and press down to

compress the seal when fitting the
securing screws.

Push the front panel up behind the top

panel and push in at the base to secure
the screws with the tool provided.

After service handover:

Make a note of the date of any water treatment.
Set the controls back to the users

requirements.

Complete the service interval record at the

back of this manual and a CD11 or an
equivalent form.

If the appliance is unused and exposed to

freezing conditions; shut off all the mains
supplies, isolate the boiler and drain the
system and boiler, including the secondary
heat exchanger.

%CO

2

NOMINAL BOILER RATING AT NORMAL OPERATING
TEMPERATURE USING 28sec KEROSENE:

NOZZLE

12/18 - Bentone Sterling 40 Burner:

OIL PUMP

PRESSURE

(p.s.i.)

FUEL

FLOW RATE

Kg/h

l/h

APPROX.

FLUE GAS

TEMP

°C

APPROX.

AIR

SETTING

APPLIANCE

INPUT

OUTPUT

kW

Btu/hr

kW

Btu/hr

0.35 80

°SR

0.45 80

°S

0.50 80

°ES

115

115

140

1.04

1.29

1.55

1.32

1.63

1.96

66

70

73

11.5

12.0

12.5

2.5

4.5

5.25

42300

52900

63500

12

15

18

40900

51200

61400

12.4

15.5

18.6

25/32 - Riello RDB Burner:

0.75 60

°ES

0.75 60

°ES

0.85 60

°ES

105

140

150

2.15

2.45

2.75

2.72

3.1

3.48

78

80

83

11.5

12.0

12.5

3.0

4.0

5.0

87000

99300

111600

25

28.5

32

85300

97200

109200

25.5

29.1

32.7

18/25 - Bentone Sterling 50 Burner:

0.50 80

°EH

0.55 80

°EH

0.65 80

°EH

130

145

150

1.56

1.86

2.17

1.98

2.36

2.75

72

79

82

11.5

12.0

12.5

4.25

6.0

8.0

63500

75750

88000

18

21.5

25

61400

73400

85300

18.6

22.2

25.8

E

A

B

C

D

F