X 2 1 – Sharp R-1900M User Manual

Page 17

Advertising
background image

16

NOTES:
1. Only Dual Digit Input method can be used when inputting

memory numbers in Multiplication Factor for Double/Triple
Quantity.

2. The multiplication factors can be set from 0.01 to 9.99 for

double quantity and triple quantity.

3. When you want to know the multiplication factor for triple

quantity, press the DOUBLE/TRIPLE QUANTITY twice at
step 1 after pressing the CUSTOM SETTING pad twice.

4. Multiplication Factors for Double/Triple Quantity can be

checked or changed before pressing the STOP/CLEAR pad
to exit for Custom Setting Function.

11. Express Defrost Setting
Express Defrosting uses 3 stages to defrost foods quickly.
The defrosting sequence is preset as follows, but you can
change the setting.

Defrosting Time

Power Level

STAGE

1

T x A1: (0.20*) + B1: (20*) sec.

PL1 (40*) %

STAGE

2

T x A2: (0.13*) + B2: (30*) sec.

PL2 (30*) %

STAGE

3

T - STAGE1 - STAGE2

PL3 (20*) %

Pause

Timing

See the table for The Pause
Timing below (50*)

T : INPUT TIME (TOTAL COOKING TIME)
* : The numbers in the parentheses are factory settings

and can be adjusted.

Express Defrost is preset to pause during the sequence
when 50% of total defrosting time has passed to check food.
Pause timings can also be adjusted.

Pause Timing

KEY

Display

Pause Timing

0

0

No pause.

1

1

After 10% of total cooking time.

2

2

After 20% of total cooking time.

3

3

After 30% of total cooking time.

4

4

After 40% of total cooking time.

5

5

After 50% of total cooking time.

6

6

After 60% of total cooking time.

7

7

After 70% of total cooking time.

8

8

After 80% of total cooking time.

9

9

After 90% of total cooking time.

START

A

After ending of each stage

2 Press the MANUAL/

REPEAT pad and enter
desired multiplication for
A1 at Stage 1.

(Ex: Enter 3,0 for 0.30.)

4 Press the POWER LEVEL

pad and enter desired
power level for PL1 at
Stage 1.

(Ex: Enter 5 for 50%)

* Suppose you want to change the Express Defrost set

factory settings to the following:

Defrosting Time

Power Level

STAGE 1

T x 0.30 + 10 sec.

50%

STAGE 2

T x 0.15 + 20 sec.

20%

STAGE 3

T - STAGE1 - STAGE2

10%

Pause
Timing

When 70% of total defrosting time has
passed.

Procedure

Display

1 Press the CUSTOM

SETTING pad twice
within 2 seconds and
press the EXPRESS
DEFROST pad.

(The Express Defrost
setting of each phase
is shown for 1.5
seconds at 0.3 second
intervals until the
MANUAL/REPEAT pad
is pressed.)

x 2

1

DEF.

DEF.

DEF.

3

0

DEF.

5

DEF.

DEF.

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

CHECK

DEF.

(STAGE 1)

(A1)

(B1)

(Power Level 1)

(STAGE 2)

(A2)

(B2)

(Power Level 2)

(STAGE 3)

(Pause Timing)

(Power Level 3)

3 Press the MANUAL/REPEAT

pad and enter desired time
for B1 at Stage 1.

(Ex: Enter 1 for 10 seconds.)

R-1900M [EN].indd Sec1:16

R-1900M [EN].indd Sec1:16

7/4/09 9:50:02 AM

7/4/09 9:50:02 AM

Advertising