Service mode, Setting up the baud rate, Available baud rates – Barco R9001490 User Manual

Page 83: Installing the interface standard, Rs422 termination

Advertising
background image

Service Mode

9-6

5976072 BARCOELM R12 05052000

Setting up the Baud rate

To change the baud rate, handle as follow :

1 Push the cursor key é or ê to highlight 'Baudrate' (menu 1).

The actual baud rate will be displayed.

2 Press ENTER to toggle between the available baudrates.

Default : 9600

Select with

é

or

ê

then <ENTER>

<EXIT> to return.

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [

115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [ON]

menu 1

Available Baud rates

115200/57600/38400/19200/9600/4800/1200

Installing the Interface Standard

The communication protocol for the communication between the projector and a computer can be set on RS232 or RS422.

To set up the desired protocol, handle as follow :

1 Push the cursor key é or ê to highlight 'Interface Standard' (menu 1).

The actual interface standard will be displayed.

2 Press ENTER to toggle between RS232 and RS422.

Default : RS232

Select with

é

or

ê

then <ENTER>

<EXIT> to return.

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [

RS232

]

RS422 TERMINATION [ON]

menu 1

RS422 Termination

The last projector in a line should be RS422 terminated (ON position). All others in the line should be in the OFF position.

To change the termination position :

1 Push the cursor key é or ê to highlight 'RS422 Termination' (menu 1).

The actual setting will be displayed.

2 Press ENTER to toggle between ON and OFF.

Default setting : ON

Select with

é

or

ê

then <ENTER>

<EXIT> to return.

SERIAL COMMUNICATION

PROJECTOR ADDRESS 001

BAUDRATE [115200]

INTERFACE STANDARD [RS232]

RS422 TERMINATION [

ON

]

menu 1