Customizing a host name, Customizing a chassis name – Brocade Communications Systems Brocade VDX 8770-4 User Manual

Page 46

Advertising
background image

26

Brocade VDX 8770-4 Hardware Reference Manual

53-1002563-02

Customizing a host name

3

NOTE

To protect the Ethernet port from damage, keep the cover on the port when not in use.

Perform the following steps to establish an Ethernet connection to the Brocade VDX 8770-4.

1. Remove the shipping plug from the Ethernet port on the active MM.

2. Insert one end of an Ethernet cable into the Ethernet port.

3. Connect the other end to an Ethernet 10/100/1000 BaseT LAN.

The Brocade VDX 8770-4 can be accessed through a remote connection using the command
line by way of Telnet or any of the management tools, such as Brocade Network Advisor.

4. To complete any additional Brocade VDX 8770-4 configuration procedures through a Telnet

session, log in to the Brocade VDX 8770-4 by Telnet using the admin login. The default
password is password.

Customizing a host name

This procedure is optional.

While still in Telnet you can change the host (switch) name of the switch. The host name of the
Brocade VDX 8770-4 can be up to 30 characters long using Network OS release 3.0.0 or later, can
include letters, numbers, hyphens, and underscore characters, and must begin with a letter. The
default host name is “sw0.” The host name is displayed at the system prompt.

1. Enter switch-attributes followed by the Rbridge ID and the host-name operand with the new

name.

If you have changed the Rbridge ID, be sure to use that ID.

switch(config)# switch-attributes 1 host-name rack1_8770_4

2. Record the new name for reference.

3. To verify the new host name you can run the show running-config command in EXEC mode.

switch# show running-config

Customizing a chassis name

This procedure is optional.

While still in Telnet you can change the chassis name of the switch. The chassis name of the
Brocade VDX 8770-4 can be up to 30 characters long; can include letters, numbers, hyphens, and
underscore characters; and must begin with a letter. The default chassis name is “VDX8770-4.”

Brocade recommends that you customize the chassis name for each platform because some of the
system logs refer to the platform by its chassis name.