Determining the status of a management module, Figure 7, Manageme – Brocade Communications Systems Brocade VDX 8770-4 User Manual

Page 60: Table 10

Advertising
background image

40

Brocade VDX 8770-4 Hardware Reference Manual

53-1002563-02

Determining the status of a management module

4

Determining the status of a management module

You must have at least one management module (MM) active for the chassis to be functional. For
redundancy, you need two MMs. The active MM is designated by the blue Active LED on the front
panel.

Complete the following steps to determine the status of a MM.

1. Check the LED indicators on the module (

Figure 7

). The LED patterns may temporarily change

during POST and other diagnostic tests. For information about how to interpret the LED
patterns, refer to

Table 10

.

2. You can use the show mm command to see whether the management modules are enabled.

You can also run the show interface management 1/1 to see the configuration information.

Figure 7

identifies the management module.

FIGURE 7

Management module

Table 10

describes the management module LED patterns and the recommended actions for those

patterns.

1

Status LED

5

Ethernet port (Mgmt IP)

2

Power LED

6

USB port

3

Active LED

7

Ethernet port (Service IP)

4

Console port (Serial)

TABLE 10

Management module LED descriptions

LED purpose

Color

Status

Recommended action

Power

Steady green

MM

is powered on.

No action required.

No light (LED is off)

MM

is not powered on.

Ensure that the module is firmly
seated and has power.

Status

No light (LED is off)

MM

is either healthy or does

not have power.

Verify that the power LED is on.

Steady amber

MM

requires attention or is

still booting up.

If the LED remains amber, the
module is faulty. Consult the
Brocade VDX 8770-4 supplier.

2

4

7

5

6

3

1

Advertising