Fluid Management Customer Service 1 . 800 . 462 . 2466

Accutinter 1500 | 33

Maintenance, Care and Use - Accutinter 1500 HS

Your Accutinter 1500 HS depends on clean and well maintained parts. To ensure dispensing accuracy and
increase the operation of your Accutinter 1500 HS, follow the maintenance schedule detailed below:

*This should be performed by a Fluid Management authorized service technician.

PERFORM EVERY DAY:
• Clean each of the nozzles with the recommended nozzle cleaning tool and purge (see below).
• Remove all excess colorant and debris from the nozzle and nozzle area.
• Clean all accessible surfaces and cabinet with a mild cleaning solution.
• Empty and clean the drip tray. Replace if necessary.
• Moist sponge daily to keep colorant from drying.
PERFORM EVERY WEEK:
• Clean the spill trays around canisters.
PERFORM EVERY SIX MONTHS:
• Check the calibration and re-calibrate as required.*

Your Accutinter 1500 HS will perform best if the nozzle and colorant lines are purged and cleaned every day. If
you use your machine frequently, Fluid Management recommends cleaning and purging the nozzle at least once
a day. The instructions for daily nozzle cleaning are below. For filling the colorant canisters, go to page 17.
Do not clean the equipment with a water jet.

Open nozzle closer

. Click Maintenance (F11)
. Choose Purge tab
. Click Open/Close (F7)

Replace sponge

. Replace sponge insert
. Moisten sponge with water
. Replace cup holder to closer

bracket

Remove cup holder from

nozzle closer

. Slide black cup holder left
. Remove cup from bracket

and place to the side

Replace cup holder to

nozzle closer

Clean nozzle

. Clean each opening with

included nozzle cleaning pick

. Use a circular motion to make

sure opening is clear

Purge colorants

. Click Maintenance (F11)
. Choose Purge tab
. Click All
. Click Purge (F3)
. Click Dispense (F2)

Clean cup

. Remove sponge insert
. Clean inside of cup liner with

water and paper towel

Close nozzle closer

. Click Maintenance (F11)
. Choose Purge tab
. Click Open/Close

NOTE:

Environmental Conditions: Operating temperature between 50

0

F (10

0

C) and 104

0

F (40

0

C)

The A-weighted sound pressure is below 70 dB.