Equipment troubleshooting

PROBLEM

FIRST CHECK:

ACTION

The nozzle closer is not

opening or closing.

…Is the nozzle closer

covered with dried colorant

and debris?

ƒ

Clean all dried colorant

and debris from the

nozzle closer area. Make

sure the nozzle arm is clean

so it moves freely.

ƒ

If the nozzle closer still does

not close, call

Customer

Service.

Colorant drips or runs

after dispensing.

…Is ColorPro prompting you

to fill the canister?

...Do the nozzle openings

need to be cleaned?

…Does the colorant have air

in it?

1- If yes, fill the canister with

colorant (see page 16).

2- Agitate for up to three

minutes.

3- Purge the line.

ƒ

If the canister is full, clean the

nozzle and complete a purge

using ColorPro (

see page 28

).

Repeat if necessary.

ƒ

Complete a purge using

ColorPro (

see page 28

).

Repeat if necessary.

A colorant canister needs

to be filled.

ƒ

Follow the “

Preparing

and refilling canisters

instructions on page 16.

The canister cover and

lids need to be cleaned.

ƒ

Soak the canister covers in

hot water and mild detergent.

Wipe off the excess debris

and dried colorant when the

colorant has loosened.

ƒ

Scrape the excess colorant

off with a putty knife.

The colorant coming out

of the nozzle is drippy or

clumpy.

...Do the nozzle openings

need to be cleaned?

ƒ

Clean the nozzle openings

and purge the lines (

see pages

33/34

). The colorant should

come out of the nozzle in a

steady stream.