W Y R G

W

IR

ES

4 Wire Heat/Cool

STEP 1 - Connect the W wire to the W terminal. This connects the heat.

STEP 2 - Connect the Y wire to the Y terminal. This connects the cooling compressor.

STEP 3 - Connect the RH or R wire to the RH terminal. This connects the power.

STEP 4 - Connect the G wire to the G terminal on the thermostat.

This connects the fan.

STEP 5 - Optional - Connect the C wire to the C terminal.

Your HVAC system is now connected to the CT100.

Please Go To Page 6

W Y RH RC G

W

IR

ES

5 Wire HEAT/Cool

STEP 1 - Connect the W wire to the W terminal. This connects the heat.

STEP 2 - Connect the Y wire to the Y terminal. This connects to the cooling compressor.

STEP 3 - Remove the jumper between RC and RH terminals [small silver wire].

STEP 4 - Connect the RH wire to the RH terminal and the RC wire to the RC terminal.

This connects the power.

STEP 5 - Connect the G wire to the G terminal. This connects the fan.

STEP 6 - Optional - Connect the C wire to the C terminal.

Your HVAC system is now connected to the CT100.

Please Go To Page 6

HVAC SYSTEM

THERMOSTAT TERMINALS

C B O W W

2

Y Y

2

R

H

RC G A

POWER

W Y R

G

C

HVAC SYSTEM

THERMOSTAT TERMINALS

C B O W W

2

Y Y

2

R

H

RC G A

POWER

W Y R

H

G

C

R

C

*R

C and

R

H

disconnected

Advertising