or

B AUX

n

Y

n

R G

Multi-stage Heat Pump with Multi-stage Aux Heat

The CT100 can handle up to 2 stages of Pump compression and 2 stages of AUX heat.

STEP 1 - Connect O wire to the O terminal or B wire to the B terminal. This connects the change-over valve.

If you have both O and B - connect only the O wire to the O terminal and DO NOT connect B to B

terminal (see wire reference under Trane for B wire terminal).

STEP 2 - Connect the AUX 1, AUX 2, to the AUX 1 and 2 respectively.

This connects the auxiliary heat.

STEP 3 - Connect the Y and Y2 wires to the Y terminals.

This connects the compressor.

STEP 4 - Connect the R wire to RH terminal. This connects the power.

STEP 5 - Connect the G wire to G terminal. This connects the fan.

STEP 6 - Optional - Connect the C wire to the C terminal.

Your HVAC system is now connected to the CT100.

Please Go To Page 6

Accessory Wiring -

3 Wire Zoned Hot Water Heat -

For 3 wire solenoid or motor valves connect the wires shown to

the correct terminals on the CT100. If you have different letters

than shown, go to page 18 Wire Reference Table.

SOLENOID VALVE

W

A

RH

CT100

MOTOR VALVE

W

RH A

CT100

FOR 3WIRE ZONED
HOT WATER

W

R

A

W

R

A

HVAC SYSTEM

THERMOSTAT TERMINALS

C B O W W

2

Y Y

2

R

H

RC G A

POWER

B

G

R

Y Y

2

C

O

or

or

AUX1 AUX2