Wire reference table, Wire reference – 2GIG CT100 User Manual

Page 17

Advertising
background image

16

PG

17

Wire Reference Table

Possible Wires

What They Control

R or V or VR

RH

and RC Single power for HEAT and COOL

RH or 4

RH

Power for HEAT (RH not connected to RC jumper wire removed)

RC

RC

Power for COOL (RH not connected to RC jumper wire removed)

W

W

Heat control

W2

W2

2nd stage HEAT

AUX or AUX1

AUX1

1st stage of AUX heat in the CT100

AUX2

AUX2

2nd stage of AUX heat in the CT100

Y

Y

COOL control or 1st stage compression for heat pump

Y2

Y2

2nd stage COOL control or 2nd stage compression for a heat pump

G or F

G

FAN control

C or X

C

24VAC power (to power thermostat)

NOTE: TRANE, AMERICAN STANDARD and YORK often use the letter B for C

H

H

External Humidiier

DH

DH

External Dehumidiier

EX

EX

external fresh air bafle

B

B

Heat pump changeover (cool to heat, powered in heat)

O

O

Heat pump changeover (heat to cool, powered in cool)

B and O

IMPORTANT: If there are both B and O wires (Trane pump

products) DO NOT CONNECT B to B terminal, connect B to C

terminal.

E

n/a Emergency heat (do not connect, tape off)

L

n/a System monitor (do not connect, tape off)

T

n/a Outdoor sensor (do not connect, tape off)

Wire Reference