Snorkel TB120 2001 User Manual

Page 52

Advertising
background image

8. EMERGENCY OPERATION

8 - 3

P/N 0191914

T

EMERGENCY OPERATION FROM THE

GROUND-CONTROL BOX

Try Procedure C first. If Procedure C does not
work, try Procedure D second and Procedure E
third.

z

z Procedure C

1

1. Set the BATTERY switch (1) to ON.

2. Set the MASTER KEY SWITCH (2) to ON.

3. Pull the EMERGENCY STOP switch (3) out
(on).

4. Set the SELECTOR SWITCH (4) to GROUND.

5. Push and hold the GROUND OPERATION
switch (5) up.

6. Push and hold any of the five platform-moving
switches (7) to move the platform as desired.

7. Push and hold the EMERGENCY POWER
OPERATION
switch (6) down and the platform
will move.

NOTE: Boom movements will be slow and
have long lag times under EMERGENCY
POWER OPERATION
.

z

z Procedure D

If the red EMS WARNING light (1) is on, try to
reset it by pressing it in then releasing it several
times. If the red light goes out, try to restart the
motor and lower the platform in the normal way.

If the red light stays on and the green EMS
STATUS
light (2) is on, the main boom can be
retracted in the normal way (if it is extended) or
lowered in the normal way (if it is almost
completely retracted). Use one or the other of
those two functions to retrieve the platform as
long as the green EMS STATUS light is on.

NOTE: If the green light goes out, try to reset
the red EMS WARNING light again to see if
the green light will come back on.

If the red light stays on and the green light stays
off, continue with this procedure.

Advertising