SECTION 6 - JLG CONTROL SYSTEM

3121298

– JLG Lift –

6-35

H & T LIGHTS:
14

0
1

NO: No head and tail lights installed.
YES: Head and tail lights installed.

0

CABLE SWITCH:
15*

0
1

NO: No broken cable switch installed.
YES: Broken cable switch installed.

0

* Certain market selections will alter default setting.

LOAD SYSTEM:
16*

0

1

2

3

4

NO: No load sensor installed.

WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5
sec ON, 2 sec OFF).

CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm
beeps (5 sec ON, 2 sec OFF).

CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS
off ), platform alarm beeps (5 sec ON, 2 sec OFF).

SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out
& main lift up, platform alarm beeps (5 sec ON, 2 sec OFF).

0

* Only visible under certain market selections.

* Certain market selections will limit load system options or alter default setting.

LOAD SENSOR:
17*

0

1

1 ON ROTATOR: Use the on-board load sensor for all models except those
which use the Leveling Platform Module.

4 UNDER PLATFORM: Use the EIM for load sensing.

1

* Only visible under certain market selections.

* Certain market selections will limit load system options or alter default setting.

Table 6-5. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default