JLG 660SJ Service Manual User Manual

Page 282

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-36

– JLG Lift –

3121298

FUNCTION CUT-
OUT:
18*

0
1
2
3

NO: No drive cutout.
BOOM CUTOUT: Boom function cutout while driving above elevation.
DRIVE CUTOUT: Drive cutout above elevation.
DRIVE CUT E&T: Drive cutout above elevation and tilted.

0

* Only visible under certain market selections.

* Certain market selections will limit function cutout options or alter default setting.

GROUND ALARM:
19*

0
1
2
3

NO: No ground alarm installed.
DRIVE: Travel alarm sounds when the drive function is active (Option).
DESCENT: Descent alarm sounds when lift down is active (Option).
MOTION: Motion alarm sounds when any function is active (Option).

3

* Certain market selections will alter default setting.

DRIVE:
20*

0
1
2

4 WD: Four wheel drive.
2WD: Two wheel drive.
2WD W/2-SPEED: Two wheel drive with two-speed valve.

0

* Only visible under certain market selections.

DISPLAY UNITS:
21*

0
1

IMPERIAL: DEG F, PSI, LBS
METRIC: DEG C, KPA, KGS.

0

* Certain market selections will alter default setting.

LEVELING MODE:
22*

0
1

ALL: Platform level with all functions.
LEVEL LIFT /TELESCOPE: Platform level on lift and telescope only.

0

* Only visible on 800S models.

DRIVE CONTROL:
23

0
1
2

NORMAL: Drive coils are energized from the Ground Module.
PROPULSION: Drive coils are energized from the Propulsion Module.
ENHANCED: Drive coils are energized from the Ground Module and the
ground side of the drive coils are brought back to current feedback returns.

2

BOOM CONTROL:
24

0
1

NORMAL: Boom control coils are energized from the Ground Module.
ENHANCED: Boom control coils are energized from the Ground Module and
the ground side of the drive coils are brought back to current feedback
returns.

0

Table 6-5. Machine Configuration Programming Information