10 generator, Every 250 hours, Every 500 hours – JLG 660SJ Service Manual User Manual

Page 96: Generator -52, Every 250 hours -52 every 500 hours -52, Generator belt tension -52, Generator brushes and slip rings -52, Generator cleaning -52, Coupling port information table - 2ws -52, Coupling port information table - 4ws -52

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-52

– JLG Lift –

3121298

3.10 GENERATOR

Every 250 hours

Check drive belt tension every 250 hours of operation,.

Figure 3-69. Generator Belt Tension

Every 500 hours

Service generator brushes and slip rings every 500 hours of
operation. Hostile environments may require more frequent
service.

Figure 3-70. Generator Brushes and Slip Rings

Blow out inside of generator every 500 hours of service. If
operating in a hostile environment, clean monthly.

Figure 3-71. Generator Cleaning

Table 3-9. Coupling Port Information Table - 2WS

Port

No.

Outlet

Port

Size

Description

Operating

Pressure
PSI (Bar)

Proof

Pressure
PSI (Bar)

1

1

-8

Brake

450 (31)

675 (47)

2

2

-6

2 Speed

4500 (310)

6750 (465)

3

1

-6

Steer

2500 (172)

3750 (259)

4

1

-6

Steer

2500 (172)

3750 (259)

5

2

-6, -16

Drive Reverse

4500 (310)

6750 (465)

6

1

-16

Drive Forward

4500 (310)

6750 (465)

7

3

-8, -6

Case Drain

250 (17)

375 (26)

Table 3-10. Coupling Port Information Table - 4WS

Port

No.

Outlet

Port

Size

Description

Operating

Pressure
PSI (Bar)

Proof

Pressure
PSI (Bar)

1

1

-8

Brake

450 (31)

675 (47)

2

2

-6

2 Speed

4500 (310)

6750 (465)

3

1

-6

Steer

2500 (172)

3750 (259)

4

1

-6

Steer

2500 (172)

3750 (259)

5

2

-6, -16

Drive Reverse

4500 (310)

6750 (465)

6

1

-16

Drive Forward

4500 (310)

6750 (465)

7

3

-8, -6

Case Drain

250 (17)

375 (26)

8

1

-6

Steer

2500 (172)

3750 (259)

9

1

-6

Steer

2500 (172)

3750 (259)

1/2 in.

(13 mm)

Advertising
This manual is related to the following products: