7 propane fuel system pressure relief, 8 supplemental information – JLG 800A_AJ Operator Manual User Manual

Page 144

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-36

– JLG Lift –

3121209

6.7 PROPANE FUEL SYSTEM PRESSURE RELIEF

THE PROPANE FUEL SYSTEM OPERATES AT PRESSURES UP TO 312
PSI (21.5 BAR). TO MINIMIZE THE RISK OF FIRE AND PERSONAL
INJURY, RELIEVE THE PROPANE FUEL SYSTEM PRESSURE (WHERE
APPLICABLE) BEFORE SERVICING THE PROPANE FUEL SYSTEM COM-
PONENTS.

To relieve propane fuel system pressure:

1. Close the manual shut-off valve on the propane fuel

tank.

2. Start and run the vehicle until the engine stalls.

3. Turn the ignition switch OFF.

RESIDUAL VAPOR PRESSURE WILL BE PRESENT IN THE FUEL SYS-
TEM. ENSURE THE WORK AREA IS WELL VENTILATED BEFORE DIS-
CONNECTING ANY FUEL LINE.

6.8 SUPPLEMENTAL INFORMATION

The following information is provided in accordance with the
requirements of the European Machinery Directive 2006/42/
EC and is only applicable to CE machines.

For electric powered machines, the equivalent continuous A-
Weighted sound pressure level at the work platform is less
than 70dB(A)

For combustion engine powered machines, guaranteed
Sound Power Level (LWA) per European Directive 2000/14/
EC (Noise Emission in the Environment by Equipment for
Use Outdoors) based on test methods in accordance with
Annex III, Part B, Method 1 and 0 of the directive, is 104 dB.

The vibration total value to which the hand-arm system is
subjected does not exceed 2,5 m/s

2

. The highest root mean

square value of weighted acceleration to which the whole
body is subjected does not exceed 0,5 m/s

2

.

Advertising