SECTION 4 - MACHINE OPERATION

4-2

– JLG Lift –

3121209

TO AVOID FORWARD OR BACKWARD TIPPING, DO NOT OVERLOAD
MACHINE OR OPERATE ON AN OUT-OF-LEVEL SURFACE.

4.3 ENGINE OPERATION

NOTE: Initial starting should always be performed from the

Ground Control station.

Starting Procedure

1. Check engine oil. If necessary, add oil in accordance

with the Engine Manufacturer’s manual.

2. Check fuel level. Add fuel if necessary.

3. Check that air cleaner components are in place and

securely fastened.

IF ENGINE FAILS TO START PROMPTLY, DO NOT CRANK FOR AN
EXTENDED PERIOD. SHOULD ENGINE FAIL TO START ONCE AGAIN,
ALLOW STARTER TO “COOL OFF” FOR 2-3 MINUTES. IF ENGINE FAILS
AFTER SEVERAL ATTEMPTS, REFER TO ENGINE MAINTENANCE MAN-
UAL.

MACHINES WITH DIESEL ENGINES. AFTER TURNING ON IGNITION,
OPERATOR MUST WAIT UNTIL GLOW PLUG INDICATOR LIGHT GOES
OUT BEFORE CRANKING ENGINE.(IF EQUIPPED)

4. Turn key of SELECT switch to GROUND. Position

POWER/EMERGENCY STOP switch to ON, then push
the ENGINE START switch to the upward position until
engine starts.

ALLOW ENGINE TO WARM-UP FOR A FEW MINUTES AT LOW SPEED
BEFORE APPLYING ANY LOAD.

5. After engine has had sufficient time to warm up, shut

engine off.

6. Turn key of SELECT switch to PLATFORM.

7. From Platform position POWER/EMERGENCY STOP

switch to ON, then push the ENGINE START switch to
the forward position until engine starts.

NOTE: Footswitch must be in released (up) position before

starter will operate. If starter operates with footswitch in
the depressed position, DO NOT OPERATE MACHINE.