JLG 800A_AJ Operator Manual User Manual

Page 57

Advertising
background image

SECTION 3 - MACHINE CONTROLS AND INDICATORS

3121209

– JLG Lift –

3-17

light will go out and the footswitch must be released and
depressed again to enable the controls.

Releasing the footswitch removes power from all con-
trols and applies the drive brakes.

TO AVOID SERIOUS INJURY, DO NOT REMOVE, MODIFY OR DISABLE
THE FOOTSWITCH BY BLOCKING OR ANY OTHER MEANS.

FOOTSWITCH MUST BE ADJUSTED IF FUNCTIONS ACTIVATE WHEN
SWITCH ONLY OPERATES WITHIN LAST 1/4" OF TRAVEL, TOP OR BOT-
TOM.

2. Engine Malfunction Indicator

On machines prior to S/N 62045, the light turns on and
an alarm sounds when machine’s power system
requires immediate service. Any of the following condi-
tions will turn on light and alarm: low engine oil pres-
sure, high engine coolant temperature, clogged engine
air filter, low alternator output, clogged hydraulic oil
return filter, or clogged charge pump filter.

On machines from S/N 62045 to present, the light indi-
cates that the JLG Control System has detected a mal-
function and a Diagnostic Trouble Code has been set in
the system memory. Refer to the Service Manual for
instructions concerning the trouble codes and trouble
code retrieval.

The malfunction indicator light will illuminate for 2-3 sec-
onds when the key is positioned to the on position to act
as a self test.

Advertising