Machine configuration programming information, Machine configuration programming information -7 – JLG E300 Service Manual User Manual

Page 131

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3120772

– JLG Lift –

6-7

Machine Configuration Programming
Information

Table 6-2. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number

NOTE: When configuring the E450, E400, or the E300 machine, the machine configuration must be completed

before any personality settings can be changed. Changing the personality settings first and then changing
the model number of the machine configuration will cause the personality settings to return to default val-
ues.

1
(Model #)

1

2

3

Model 300

Model 400(* See Note Below)

Model 45/450(*See Note Below)

1

NOTE: The elevated drive speed setting must be changed to 10% for E45AJ, M45AJ, M40AJP, E40AJP, M450AJ,

E450AJ, M400AJP, E400AJP, E400A, AND M400A machines going to Europe (CE). Also the elevated drive
speed setting must be changed to 15% for E40AJPn, M40AJPn, E400AJPn, M400AJPn,E400Anarrow, and
M400Anarrow machines going to Europe (CE).

2
(Tilt Switch)

1

2

3

4

5 degree-reduces the maximum speed of all boom functions to creep when tilted and
above elevation. Reduces drive speed to creep when tilted. Domestic and Japan

3 degree-reduces the maximum speed of all boom functions to creep when tilted and
above elevation. Reduces drive speed to creep when tilted. European and Australian

3 degree-cuts out drive and reduces boom functions to creep speed when tilted and
above elevation. Reduces drive speed to creep when tilted only. Option

3 degree- cuts out drive, telescope out, upper boom lift up and reduces all other boom
functions to creep speed when tilted and above elevation. Option

1

NOTE: Any of the selections above will light the tilt lamp when a tilted condition occurs and will sound the platform

alarm when the machine is tilted and above elevation.

3
(Drive Cutout)

0

1

2

Battery Charger Cutout-cuts out drive when the battery charger is plugged in.

Battery Charger Cutout and Simultaneous Drive and Boom Functions disabled above
elevation. Europe and Australia

Battery Charger Cutout and Drive Cutout above elevation. Option

0

4
(Function Cutout Limit
Switch)

0

1

2

No Function Cutout

Cuts out all boom functions when switch opens. Option

Cuts out all functions when switch opens. Option

0