Machine personality settings, Machine personality settings -9, Personality ranges/defaults -9 – JLG E300 Service Manual User Manual
Page 133
SECTION 6 - JLG CONTROL SYSTEM
3120772
– JLG Lift –
6-9
Machine Personality Settings
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-3. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
DRIVE
ACCELeration
0.5s to 5.0s
1.5
DECELeration
0.1s to 2.0s
0.5
MINimum speed
0 to 25%
3
MAXimum speed
0 to 100%
95
ELEVATED MAXimum speed
0 to 25%
20
CREEP MAXimum speed
0 to 45%
30
POSITRAC time
0 to 60s
10
POSITRAC current
50-250 A
170A
LOWER LIFT
ACCELeration
0.5 to 5.0s
1.0
DECELeration
0.0 to 3.0s
0.5
MINimum UP speed
0 to 30%
11
MAXimum UP speed
0 to 100%
100
MINimum DOWN speed
0 to 20%
9
MAXimum DOWN speed
0 to 100%
70
UPPER LIFT
ACCELeration
0.5 to 5.0
1.0
DECELeration
0.1 to 5.0
0.3
MlNimum UP speed
0 to 20
4
MAXimum UP speed
0 to 100
90
CREEP Maximum UP speed
0 to 50
27
MINimum DOWN speed
0 to 10
1
MAXimum DOWN speed
0 to 100
80
CREEP maximum DOWN speed
0 to 30
18