Machine personality settings, Machine personality settings -9, Personality ranges/defaults -9 – JLG E300 Service Manual User Manual

Page 133

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3120772

– JLG Lift –

6-9

Machine Personality Settings

NOTE: Personality settings can be adjusted within the

adjustment range in order to achieve optimum
machine performance.

Table 6-3. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS

DRIVE

ACCELeration

0.5s to 5.0s

1.5

DECELeration

0.1s to 2.0s

0.5

MINimum speed

0 to 25%

3

MAXimum speed

0 to 100%

95

ELEVATED MAXimum speed

0 to 25%

20

CREEP MAXimum speed

0 to 45%

30

POSITRAC time

0 to 60s

10

POSITRAC current

50-250 A

170A

LOWER LIFT

ACCELeration

0.5 to 5.0s

1.0

DECELeration

0.0 to 3.0s

0.5

MINimum UP speed

0 to 30%

11

MAXimum UP speed

0 to 100%

100

MINimum DOWN speed

0 to 20%

9

MAXimum DOWN speed

0 to 100%

70

UPPER LIFT

ACCELeration

0.5 to 5.0

1.0

DECELeration

0.1 to 5.0

0.3

MlNimum UP speed

0 to 20

4

MAXimum UP speed

0 to 100

90

CREEP Maximum UP speed

0 to 50

27

MINimum DOWN speed

0 to 10

1

MAXimum DOWN speed

0 to 100

80

CREEP maximum DOWN speed

0 to 30

18

Advertising