SECTION 4 - BOOM & PLATFORM
3120772
– JLG Lift –
4-9
NOTE: UPPER BOOM ANGLE TO BE 1° BELOW
HORIZONTAL TO 3° ABOVE HORIZONTAL
TO ACTIVATE SWITCH. UPPER BOOM
ANGLE TO BE 1° TO 4° BELOW HORIZONTAL
TO RESET SWITCH
NOTE: LOWER BOOM ANGLE TO BE 1°
TO 5° ABOVE HORIZONTAL TO ACTIVATE
SWITCH. LOWER BOOM ANGLE TO BE 0°
TO 5° BELOW HORIZONTAL TO
RESET SWITCH
SEE DETAIL A
DETAIL A
Figure 4-7. Boom Limit Switches