SECTION 3 - CHASSIS & TURNTABLE

3-106

– JLG Lift –

3120858

DTC 362 - Megajector voltage supply low.

a. Voltage - Check battery voltage. If the voltage at

the battery is less than 9.5 volts:
The battery is faulty

or

The charging system is faulty

or

The Megajector is faulty.

DTC 363 - Megajector Internal Actuator Fault Detection.

a. Connections - Check power, ground, and CAN

circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.

b. Megajector - Megajector has an internal failure.

Contact JLG Industries for further assistance.

DTC 364 - Megajector Internal Circuitry Fault Detection.

a. Connections - Check power, ground, and CAN

circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.

b. Megajector - Megajector has an internal failure.

Contact JLG Industries for further assistance.

DTC 365 - Megajector Internal Comm Fault Detection.

a. Connections - Check power, ground, and CAN

circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.

b. Megajector - Megajector has an internal failure.

Contact JLG Industries for further assistance.

3.26 ELECTRIC GOVERNOR INSTALLATION

AND ADJUSTMENTS - FORD LRG425
ENGINE (PRIOR TO S/N 0300065534)

General

These instructions presume no electrical test equipment
other than a multimeter for making the electrical measure-
ments called for on the following pages. If no suitable
meter is available, an inexpensive but adequate meter,
part number 22-188 is available from any local Radio
Shack store.

Many “governor problems” turn out to be installation
problems, particularly in first-time applications. Careful
attention to the directions provided will go far toward a
successful installation made in the least amount of time.

Quick-start Installations

If you are experienced in installing and adjusting Electric
Governor, follow these steps. Otherwise, refer to the more
detailed instructions starting with “MOUNTING-ACTUA-
TOR”.

1. Mount Actuator rigidly to engine location which will

permit a short, straight linkage to the carburetor or
fuel valve. Avoid very hot areas.

2. Mount controller in a dry, fairly cool location. Acces-

sibility for adjusting is required.

3. Wire per appropriate included schematic, using #16

wire.

4. Set up fuel linkage. This is critical, so review the sec-

tion titled “LINKAGE”.

5. Hold linkage for safety, and start engine.
6. Adjust engine speed to desired valve using High

Engine pot. Turn CW to increase, CCW to decrease
speed.

Advertising