Failure modes – JLG 800A_AJ Service Manual User Manual

Page 171

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3120858

– JLG Lift –

3-115

Failure Modes

Immediate Red Light

Action:

1. Recycle power to determine if the problem is inter-

mittent.

2. The input voltage must be greater than 10.5 Vdc.
3. Check wiring for any damage and correct.
4. Disconnect engine harness and actuator connnec-

tions.

5. If problem reoccurs return unit.

Green and either Amber light followed by a red light

or

then

Action:

1. Inspect and clean wiring connections.

2. Examine throttle linkage for any damage or bent

components and correct.

3. With linkage disconnected, check each potentiome-

ter for operation.

4. Reconnect linkage and reset each potentiometer for

correct operation.

5. If failure continues to occur, replace unit.

Only green light on and no actuator movement

Action:

1. Adjust trim potentiometers.

2. If problem continues, replace unit.

Advertising