SECTION 4 - BOOM & PLATFORM

4-44

– JLG Lift –

3120858

3. Set the ramp up and the down times. Step 2 must be

completed before continuing with this procedure.
Power up the card, but do not start the engine. Place
the current meter in series with the "A" output. Turn
the input potentiometer to its extreme position and
operate the telescope function. watch the meter for
the time it takes the output to go from 0 current to
maximum current. This is ramp up time. Adjust P1
until this time matches the time in Table 4-3. Rotating
the adjustment potentiometer clockwise will
increase ramp time. To set the ramp down time, hold
the telescope function switch and watch the time it
takes the output to go from the maximum current
down to 0 current. This is the ramp down time.
Adjust P2 until this time matches the setting time in
Table 4-3. Rotating the adjustment potentiometer
clockwise will increase the ramp time.

Table 4-2. Ramp Current Setting Range

FUNCTION

MINIMUM

CURRENT

MAXIMUM
CURRENT

UPPER LIFT UP

450 to 550 mA

1300 to 1500 mA

UPPER LIFT DOWN

450 to 550 mA

1700 to 2000 mA

(Set 450 mA higher

than Upper lift)

SWING RIGHT

450 to 550 mA

1000 to 1300 mA

SWING LEFT

450 to 550 mA

1100 to 1300 mA

(Set 100 mA higher

than swing right)

FLOW CONTROL

750 to 850 mA

1100 to 1300MA
(Set using Main Tele)

DRIVE FORWARD

20 to 60 mA

130 to 160 mA

DRIVE REVERSE

20 to 60 mA

130 to 160 mA

Figure 4-22. Control Card

Table 4-3. Ramp time Setting

FUNCTION

RAMP TIME

Lift Up

Ramp UpTime = 5:00 sec.
Ramp Down Time = 3:00 sec.

Lift Down

Ramp Up Time =5:00 sec.
Ramp Down Time =3:00 sec.

Swing Right

Ramp Up Time =7:00 sec.
Ramp Down Time =3:00 sec.

Swing Left

Ramp Up Time =7:00 sec.
Ramp Down Time =3:00 sec.

Drive Forward

Ramp Up Time =4:30 sec.
Ramp Down Time = 2:30 sec.

Drive Reverse

Ramp Up Time = 4:30 sec.
Ramp Down Time = 2:00 sec.

Flow Control

Ramp Up Time =3:00 sec.
Ramp Down Time =0.00 sec.