Pressure regulator section -139 – JLG 800A_AJ Service Manual User Manual

Page 195

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3120858

– JLG Lift –

3-139

6. Install the electric lock off into the regulator inlet and

tighten into proper location, connect the electrical
connector.

7. Connect the fuel supply line and tighten until fully

seated.

8. Connect the EPR electrical connector.

9. Open the manual valve.

10. Start the vehicle and leak check the propane fuel

system at each serviced fitting Refer to Propane Fuel
System Leak Test.

PRESSURE REGULATOR SECTION REMOVAL

1. Remove the EPR refer to EPR Removal Procedure.

2. Remove the six (6) regulator to voice coil screws

using the special tool and separate the regulator
from the actuator.

DO NOT REMOVE THE SECONDARY DIAPHRAGM RETAINING
PLATE AND DIAPHRAGM THIS WILL VOID THE WARRANTY OF
THE ACTUATOR SECTION.

PRESSURE REGULATOR SECTION INSTALLATION

1. Install the regulator to the actuator section using the

six (6) retaining screws and tighten 70 in lbs (8 Nm).

2. Install the EPR refer to EPR Installation.

Figure 3-83. Pressure Regulator Section

Advertising