Cabin Controls (23X)

Message

Fault
Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

CONFLICTING FRAME

LEVEL SIGNALS

2322

5000Ms

Frame Level Left and Frame Level

Right are prevented

UGM J4-9 Frame Level Left and UGM

J4-17 Frame Level Right digital

inputs are energized together

Power cycled

CABIN JOYSTICK – X

AXIS FAULT

2323

Continuously

Cabin joystick X-axis is prevented

Elobau Cabin Joystick configured: 

Cabin joystick transmits a DM1

(SPN:FMI) with 0Xf010:E2, 0Xf011:E2,

or 0Xf012:E2

Cabin joystick transmit 1022 as the

X-Axis position

Cabin joystick transmits Error (1:0)

for the X-Axis

Neutral, Left, or Right Position

Power cycled

CABIN JOYSTICK – Y

AXIS FAULT

2324

Continuously

Cabin joystick Y-axis is prevented

Elobau Cabin Joystick configured:

Cabin joystick transmits a DM1

(SPN:FMI) with 0Xf020:E2, 0Xf021:E2,

or 0Xf022:E2

Cabin joystick transmits 1022 as the

Y-Axis position

Cabin joystick transmits Error (1:0)

for the Y-Axis Neutral, Forward, or

Backward Position

Power cycled

CABIN JOYSTICK – UP

BUTTON FAULT

2327

Continuously

Downshift & upshift buttons are

prevented

Elobau Cabin Joystick configured:

Cabin joystick transmits Error (1:0)

for the upshift button

Cabin joystick transmits a DM1

(SPN:FMI) with 0Xf064:FF

Power cycled

CABIN JOYSTICK –

DOWN BUTTON

FAULT

2326

Continuously

Downshift & upshift buttons are

prevented

Elobau Cabin Joystick configured:

Cabin joystick transmits Error (1:0)

for the downshift button

Cabin joystick transmits a DM1

(SPN:FMI) with 0Xf065:FF

Power cycled

CABIN JOYSTICK –

AUX CONTINOUS

FAULT

2330

Continuously

AUX Continuous function requests

will be ignored by the UGM

(Continuous Auxiliary; Auxiliary

Pressure Release)

Elobau Cabin Joystick configured:

Cabin joystick transmits Error (1:0)

for the AUX Continuous Auxiliary;

Auxiliary Pressure Release) button

Cabin joystick transmits a DM1

(SPN:FMI) with 0Xf063:FF

Power cycled

HYDRAULIC FILTER

RESTRICTION

2332

5000Ms

Five minutes after engine start, UGM

J2-24 Hydraulic Filter Restriction

Switch digital input is grounded for

25,000Ms

UGM J2-24

Hydraulic Filter

Restriction

Switch digital

input is not

grounded for

1,000Ms

LOAD MOMENT

SHUTOFF INPUT –

INVALID SIGNAL

2336

5000Ms

Load Moment Shutoff Switch is

ignored

UGM J4-33 Load Moment Shutoff

digital input is energized at power

up or for 40 Seconds

Power cycled