Electrical System

9-40

3614RS, 4017RS

MAIN LIFT DOWN

VALVE – SHORT TO

GROUND

33185

Continuously

Lift Up is prevented

Lift Down is prevented

UGM J3-2 Lift Return is disabled

Short to ground is detected on UGM

J2-22

Power cycled

MAIN TELESCOPE OUT

VALVE – OPEN

CIRCUIT

33186

5000Ms

Telescope Out is prevented

Open-circuit is detected on UGM J2-

35

Power cycled

MAIN TELESCOPE

VALVES – SHORT TO

BATTERY

33187

Continuously

Telescope Out is prevented

Telescope In is prevented

UGM J3-4 Telescope Return is

disabled

Short to battery is detected on UGM

J2-34 or UGM J2-35

Power cycled

MAIN TELESCOPE OUT

VALVE – SHORT TO

GROUND

33188

Continuously

Telescope Out is prevented

Telescope In is prevented

UGM J3-4 Telescope Return is

disabled

Short to ground is detected on UGM

J2-35

Power cycled

MAIN TELESCOPE IN

VALVE – OPEN

CIRCUIT

33189

5000Ms

Telescope In is prevented

Open-circuit is detected on UGM J2-

34

Power cycled

MAIN TELESCOPE IN

VALVE – SHORT TO

GROUND

33190

Continuously

Telescope Out is prevented

Telescope In is prevented

UGM J3-4 Telescope Return is

disabled

Short to ground is detected on UGM

J2-34

Power cycled

FORK TILT UP VALVE –

OPEN CIRCUIT

33191

5000Ms

Fork Tilt Up is prevented

Fork Tilt Mode is active;

Open-circuit is detected on UGM J2-

8

Power cycled

FORK TILT VALVES –

SHORT TO BATTERY

33192

Continuously

Fork Tilt Up is prevented

Fork Tilt Down is prevented

UGM J3-6 Tilt Return is disabled

Short to battery is detected on UGM

J2-8 or J2-19

Power cycled

FORK TILT UP VALVE –

SHORT TO GROUND

33193

Continuously

Fork Tilt Up is prevented

Fork Tilt Down is prevented

UGM J3-6 Tilt Return is disabled

Fork Tilt Mode is active;

Short to ground is detected on UGM

J2-8

Power cycled

FORK TILT DOWN

VALVE – OPEN

CIRCUIT

33194

5000Ms

Fork Tilt Down is prevented

Fork Tilt Mode is active;

Open-circuit is detected on UGM J2-

19

Power cycled

FORK TILT DOWN

VALVE – SHORT TO

GROUND

33195

Continuously

Fork Tilt Up is prevented

Fork Tilt Down is prevented

UGM J3-6 Tilt Return is disabled

Fork Tilt Mode is active;

Short to ground is detected on UGM

J2-19

Power cycled

AUXILIARY

FUNCTION-A VALVE –

OPEN CIRCUIT

33196

5000Ms

Auxiliary Function-A is prevented
Continuous Auxiliary Hydraulics is

prevented

Auxiliary Release is prevented

Open-circuit is detected on UGM J2-

9

Power cycled

AUXILIARY

FUNCTION-A/B

VALVES – SHORT TO

BATTERY

33197

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Auxiliary Release is prevented

Short to battery is detected on UGM

J2-9 or UGM J2-20

Power cycled

AUXILIARY

FUNCTION-A VALVE –

SHORT TO GROUND

33198

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Auxiliary Release is prevented

Short to ground is detected on UGM

J2-9

Power cycled