JLG 4017RS Service Manual User Manual

Page 135

Advertising
background image

8-5

3614RS, 4017RS

Hydraulic System

d. Pressure Specifications

Note: All pressure check are to be performed at High Idle unless noted.

Hydraulic

Circuit

Test Port

Procedure

Adjustment

Location

Pressure Range

1

Steer Pressure

LS1 (A)

Connect gauge to LS1 port, select 2

wheel steer, run engine at high idle, turn

steering wheel one direction to lock.

Hold and check pressure.

Note: Do not operate any other function

while checking pressure.

N/A

175-185 Bar

(2538-2683 PSI)

2

Load Sense

LS1 (A)

Connect gauge to LS1 port, level boom

and bottom boom retract.

N/A

265-275 Bar

(3843-3988 PSI)

3

Maximum Pump

Pressure

P1 (B)

LS1 (A)

V (C)

Connect gauge to P1 port, retract boom

and bottom against frame. Repeat using

port LS1, then port V.

1

275-285 Bar

(3988-4133 PSI)

4

Stand-By

Pressure

P1 (B)

LS1 (A)

V (C)

Connect gauge to P1 port, check

pressure at Low idle with no function.

Repeat using port LS1, then port V.

N/A

30-34 Bar

(435- 493 PSI)

7

Auxiliary

Pressure

Auxiliary

Port

Connect gauge to Auxiliary Coupling,

check pressure at coupling.

N/A

270-290 Bar

(3916-4209 PSI)

MZ7740

A

C

B

1

Advertising
This manual is related to the following products: