Electrical system – JLG 4017RS Service Manual User Manual

Page 193

Advertising
background image

9-41

3614RS, 4017RS

Electrical System

AUXILIARY

FUNCTION-B VALVE –

OPEN CIRCUIT

33199

5000Ms

Auxiliary Function-B is prevented

Continuous Auxiliary Hydraulics is

prevented

Auxiliary Release is prevented

Open-circuit is detected on UGM J2-

20

Power cycled

AUXILIARY

FUNCTION-B VALVE –

SHORT TO GROUND

33200

Continuously

Auxiliary Function-A is prevented

Auxiliary Function-B is prevented

UGM J3-14 Aux Return is disabled

Continuous Auxiliary Hydraulics is

prevented

Auxiliary Release is prevented

Short to ground is detected on UGM

J2-20

Power cycled

STABILIZER/FRAME

LEVEL SPEED VALVE –

OPEN CIRCUIT

33201

5000Ms

Stabilizers are prevented

Frame Level is prevented

Open-circuit is detected on UGM J1-

3

Power cycled

STABILIZER/FRAME

LEVEL SPEED VALVE –

SHORT TO BATTERY

33202

Continuously

Stabilizers are prevented

Frame Level is prevented

UGM J3-5 Stabilizer / Frame Level

Speed Return is disabled

Short to battery is detected on UGM

J1-3

Power cycled

STABILIZER/FRAME

LEVEL SPEED VALVE –

SHORT TO GROUND

33203

Continuously

Stabilizers are prevented

Frame Level is prevented

UGM J3-5 Stabilizer / Frame Level

Speed Return is disabled

Short to ground is detected on UGM

J1-3

Power cycled

LEFT STABILIZER

DOWN VALVE – OPEN

CIRCUIT

33222

5000Ms

Left & Right Stabilizer Down is

prevented

Open circuit is detected on UGM J2-

21

Power cycled

LEFT STABILIZER

DOWN VALVE –

SHORT TO BATTERY

33223

Continuously

Stabilizers are prevented

Frame Level is prevented

Short to battery is detected on UGM

J2-21

Power cycled

LEFT STABILIZER

DOWN VALVE –

SHORT TO GROUND

33224

5000Ms

Left & Right Stabilizer Down is

prevented

Short to ground is detected on UGM

J2-21

Power cycled

LEFT STABILIZER UP

VALVE – OPEN

CIRCUIT

33225

5000Ms

Stabilizers are prevented

Open circuit is detected on UGM J2-

10

Power cycled

LEFT STABILIZER UP

VALVE – SHORT TO

BATTERY

33226

Continuously

Stabilizers are prevented

Frame Level is prevented

Short to battery is detected on UGM

J2-10

Power cycled

LEFT STABILIZER UP

VALVE – SHORT TO

GROUND

33227

5000Ms

Stabilizers are prevented

Short to ground is detected on UGM

J2-10

Power cycled

RIGHT STABILIZER

DOWN VALVE – OPEN

CIRCUIT

33228

5000Ms

Left & Right Stabilizer Down is

prevented

Open circuit is detected on UGM J2-

15

Power cycled

RIGHT STABILIZER

DOWN VALVE –

SHORT TO BATTERY

33229

Continuously

Stabilizers are prevented

Frame Level is prevented

Short to battery is detected on UGM

J2-15

Power cycled

RIGHT STABILIZER

DOWN VALVE –

SHORT TO GROUND

33230

5000Ms

Left & Right Stabilizer Down is

prevented

Short to ground is detected on UGM

J2-15

Power cycled

RIGHT STABILIZER UP

VALVE – OPEN

CIRCUIT

33231

5000Ms

Stabilizers are prevented

Open circuit is detected on UGM J2-

3

Power cycled