9-39

3614RS, 4017RS

Electrical System

9.13.4

Function Prevented (25X)

9.13.5

Output Drivers (33X)

Message

Fault
Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

FUNCTION

PREVENTED

25XXX

-

-

-

-

MODEL CHANGED –

HYDRAULICS

SUSPENDED – CYCLE

POWER

259

Continuously

Hydraulic functions are prevented

Engine Start is prevented

Machine Setup’s MODEL was

changed

Power cycle

FUNCTIONS LOCKED

OUT – CONSTANT

DATA VERSION

IMPROPER

2520

Continuously

Hydraulic functions are prevented

Engine Start is prevented

UGM Constant Data version does

not agree with Application

Re-program

UGM; Power

cycled

ENGINE START

PREVENTED – PARK

BRAKE NOT SET

2525

5000Ms

Engine Start is prevented

UGM J4-8 Engine Start digital input

is high (key in start position) and

UGM J4-6 Park Brake is low (not set).

UGM J4-6 Park

Brake is high

(set; 250Ms).

ENGINE START

PREVENTED – SHIFT

LEVER NOT IN

NEUTRAL

2529

5000Ms

Engine Start is prevented

UGM J4-8 Engine Start digital input

is energized;

the cabin joystick’s FNR switch is set

to forward or reverse; the cabin

column shifter FNR switch is set to

forward or reverse.

Cabin joystick’s

or column

shifter’s FNR

switch is set to

neutral

SYSTEM TEST MODE

ACTIVE

2548

5000Ms

Hydraulic functions are prevented

Engine Start is prevented

System Test has been activated

using the Analyzer

Power cycle

BOOM RETRACTED

SENSOR FAULTY –

SENSING INVALID

2560

Continuously

Boom extended (ignore J7-23Boom

Retracted Switch)

Machine Setup’s BOOM RETRACT is

YES and the J7-23 Boom Retracted

Switch becomes unhealthy

Power cycled

or boom

retracted

switch

becomes

healthy

Message

Fault
Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

OUTPUT DRIVERS

33XXX

-

-

-

-

MAIN LIFT UP VALVE –

OPEN CIRCUIT

33181

5000Ms

Lift Up is prevented

Open-circuit is detected on UGM J2-

11

Power cycled

MAIN LIFT VALVES –

SHORT TO BATTERY

33182

Continuously

Lift Up is prevented

Lift Down is prevented

UGM J3-2 Lift Return is disabled

Short to battery is detected on UGM

J2-11 or UGM J2-22

Power cycled

MAIN LIFT UP VALVE –

SHORT TO GROUND

33183

Continuously

Lift Up is prevented

Lift Down is prevented

UGM J3-2 Lift Return is disabled

Short to ground is detected on UGM

J2-11

Power cycled

MAIN LIFT DOWN

VALVE – OPEN

CIRCUIT

33184

5000Ms

Lift Down is prevented

Open-circuit is detected on UGM J2-

22

Power cycled