Electrical system – JLG 4017RS Service Manual User Manual

Page 202

Advertising
background image

Electrical System

9-50

3614RS, 4017RS

MACHINE

CONFIGURATION OUT

OF RANGE – CHECK

ALL SETTINGS

9949

Continuously

Hydraulic functions are prevented

Engine Start is prevented

ECM Power is de-energized to

shutdown engine

UGM detects a parameter range

issue with Machine Setup

Machine Setup

is properly

configured;

Power cycled

CABIN JOYSTICK –

INTERNAL FAILURE

9976

Continuously

Hydraulic functions are prevented

Direction selection shall be neutral

(If FNR configured)

Elobau Joystick configured:

Cabin joystick transmits a DM1

(SPN:FMI)

with 0Xf001:EC, 0Xf002:EC,

0Xf005:EC

Cabin joystick transmitted an

undocumented DM1 (SPN:FMI)

Power cycled

EEPROM VALUE – OUT

OF RANGE

9978

Continuously

Hydraulic functions are prevented

Engine Start is prevented

ECM power is de-energized to

shutdown engine

UGM detects a parameter range

issue with Personalities

Personalities

are properly

configured;

Power cycled

GROUND MODULE

VLOW FET FAILURE

9986

Continuously

Hydraulic functions are prevented

Engine Start is prevented

ECM power is de-energized to

shutdown engine

UGM detects a Low sense FET failure

(all high-sensing digital inputs are

high)

Power cycled

FUNCTIONS LOCKED

OUT – LSI SOFTWARE

VERSION IMPROPER

99151

Continuously

Load Moment Cutout assumed to be

100%

Load Monitoring configured;

LSI System transmitted Major /

Minor Software version that is not
compatible (P0.11 or greater; P1.x

allowed)

Power cycled

LSI FAULTY – SYSTEM

FLASH CRC ERROR

99152

Continuously

Load Moment Cutout assumed to be

100%

Load Monitoring configured;

LSI System reports Fault #1 – CRC

Error in System Flash

Power cycled

LSI FAULTY – DATA

FLASH CRC ERROR

99153

Continuously

Load Moment Cutout assumed to be

100%

Load Monitoring configured;

LSI System reports Fault #2 – CRC

Error in Data Flash

Power cycled

LSI FAULTY – LOAD

CELLS A AND B

DISAGREEMENT

99154

Continuously

Load Moment Cutout assumed to be

100%

Load Monitoring configured;

LSI System reports Fault #3 –

Excessive Data Variance between

Load Cell A and Load Cell B

Power cycled