6 engine (43x), 7 battery supply (44x), Engine (43x) – JLG 4017RS Service Manual User Manual

Page 198: Battery supply (44x), Electrical system

Advertising
background image

Electrical System

9-46

3614RS, 4017RS

9.13.6

Engine (43X)

9.13.7

Battery Supply (44X)

Message

Fault
Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

ENGINE

43XXX

-

-

-

-

ALTERNATOR

CHARGING FAILURE

4320

5000Ms

Engine running > 3,000Ms and UGM

J4-7 Alternator D+ digital input is

low

UGM J4-7

Alternator D+

is high for

3,000Ms

Message

Fault
Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

BATTERY SUPPLY

44XXX

-

-

-

-

BATTERY VOLTAGE

TOO LOW – SYSTEM

SHUTDOWN

441

-

Hydraulic functions are prevented

All digital outputs are disabled

UGM detects the battery voltage is <

9V for at least 500Ms; engine is not

cranking

Power cycled

BATTERY VOLTAGE

TOO HIGH – SYSTEM

SHUTDOWN

442

-

Hydraulic functions are prevented

All digital outputs are disabled

UGM detects the battery voltage >

16V for at least 250Ms

Power cycled

BATTERY VOLTAGE

LOW

445

5000Ms

UGM detects battery voltage < 11V

for 3,000Ms, and the engine is

running

UGM detects

battery voltage

>11V for

10,000Ms

REFERENCE VOLTAGE

OUT OF RANGE –

GROUND

447

5000Ms

Hydraulic functions are prevented

UGM detects its reference voltage is

out of range (>5.4V or <4.6V) for

1000Ms.

Power cycled