background image

48

2N TELEKOMUNIKACE a.s., www.2n.cz

®

2.4 Installation

Product Completeness Check

Before installing this product, check whether the delivery is complete according to the
following packing list and read this manual thoroughly. The manufacturer cannot be
held responsible for any damage incurred due to an incorrect use of this product in
contradiction with this manual. The warranty terms do not cover damage to the
product caused by rough handling, incorrect storage or exceeding the quoted technical
parameters.

Item

Rack with AC power supply

Rack with DC power supply

Power cable 2.5m

1

Mounting set

1

1

Quick Start manual 1

1

Serial 9F-9F cable

1

1

Table: Basic Packing List Items

Included device

1PRI
card

2PRI
card

VoIP
card

Basic CPU
card

Enhanced CPU
card

Ethernet cable
3m

1

2

1

Ethernet cable
0.6m

1

2

Table: Additional Packing List Items

Installation Conditions

The following conditions must be met during system installation:

Appropriate location (enough free space).
GSM/UMTS signal intensity (minimum recommended signal level

). You

: −80dB

can use the NET monitor on a mobile phone (e.g. Nokia, Siemens) or the
diagnostics screen in the web interface for measuring the GSM/UMTS signal
intensity.
Unoverloadable GSM/UMTS cells to which the gateway modules are logged in;
please keep in mind that up to 30 calls are set up at a time during full traffic
(according to the gateway configuration).
No strong electromagnetic radiation is allowed on the system installation site.
No strong electromagnetic reflections are allowed on the antenna installation site.
The ISDN PRI connection must be configured properly and meet the ITU-T
Q.931-EDSS1 and related recommendations.
The VoIP – SIP signalling must meet the required RFCs.

Tip

The packing lists are the same for all the gateway types (2N StarGate/

®

).

BlueTower