Power supply – 2N StarGate/BlueTower v5.4 User Manual
Page 12

12
The PRI/CPU/VoIP card positions are fixed and may not be
interchanged in the rack.
Note
Please keep all cards in the right positions. Wrong positions will
cause malfunction of the whole system!
In the case of VoIP card replacement by ISDN PRI (and vice
versa) please read the instructions in Section
Power Supply
The system uses an industrial power supply unit with natural cooling and an auxiliary
external fan, which is switched on automatically whenever the power supply
temperature exceeds 70°C. The power supply unit is designed with a 30% reserve
even under the maximum load.
Power supply types
Internal 90 – 260V / 50 – 60 Hz (output 5V / 30A).
2x Internal 90 – 260V / 50 – 60 Hz (output 5V / 30A) (redundant).
Internal 48 DC (output 5V / 30A).
The type of the power supply unit to be used depends on the part number.
Caution
Make sure that the incoming supply is matching the requested
values!
High voltage may cause a serious injury or death!
Tip
You are recommended to connect the gateway to the UPS
system.