Environmental conditions, 3 environmental conditions – ADS-TEC IWL3000 User Manual User Manual

Page 11

Advertising
background image

IWL3000 series

10

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

3.3 Environmental conditions

The device can be put into operation and used under the following conditions. Failure to observe any
one of these conditions will invalidate the warranty. ads-tec cannot be held liable for any damages
arising from improper use and handling.

Ambient temperature

during operation

-20 to 70° C

during storage

-40 to 85° C

Humidity

during operation

5 to 90%, without condensate

during storage

5 to 90%, without condensate

Vibration

during operation

1 G, 10 to 500 Hz

(DIN EN 60068-2-6)

Vibration test:

MIL-STD-810F 514.5 C-2

5 to 500 Hz (01-01-2000)

Shock resistance

during operation

5 G, with a 30 ms half-cycle

(DIN EN 60068-2-29)

Advertising