Atop Industrial Serial Device Server
SE5408A/SE5416A Series
User Manual V 1.0

78

Figure 7.6

Click on the COMX port under Serial on the left hand side.

Select UDP in the Link modes.

Destination IP and Port: Specify the Begin and End IP here. Four groups of range IPs

are allowed. This is the IP address of the UDP program and the Port it is listening to.

Note that the maximum number of UDP nodes that SE5416A Series can handle would

highly depend on the traffic load. We have tested that SE5416A Series can handle up to

100 UDP nodes (baud rate 9600 bps, request interval 100ms, and data length 30bytes).

Enter the Local Listening Port. This is the port that SE5416A Series should listen to.

Match this setting in the UDP program (usually called destination port in the UDP

program).

For serial settings, go to

Sec. 5.4.1

. For Advanced settings, go to

Sec. 5.4.2

.

Scroll to the bottom of the page and click on “Save Configuration” button to save the

changes.