7.2.10

TCP Server Application: Multi-Point TCP Pair

Connections

The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection

is that the TCP implementation would also exchange flow control pins for RS-232. However,

the TCP Server is limited to a maximum of four connections. If there are four serial devices and

they don’t use flow control pins with RS-232 or RS-485, it is possible to setup pair connection

in UDP mode,

Sec. 7.2.8

. After multi-connection is enabled in the WebUI, refer to the following

table to setup Pair Connection as in Figure 7.14.

IP Address

Link Mode

Application

Local Listening

Port

Destination

IP

Destination Port

SE5416A Master COM1

10.0.50.100

TCP Server

Pair Connection Master

4660

-

-

SE5416A Slave 1 COM1

10.0.50.200

TCP Client

Pair Connection Slave

-

10.0.50.100

4660

SE5416A Slave 1 COM2

10.0.50.200

TCP Client

Pair Connection Slave

-

10.0.50.100

4660

SE5416A Slave 2 COM3

10.0.50.200

TCP Client

Pair Connection Slave

-

10.0.50.100

4660

SE5416A Slave 3 COM1

10.0.50.201

TCP Client

Pair Connection Slave

-

10.0.50.100

4660

Figure 7.14