Atop Industrial Serial Device Server
SE5408A/SE5416A Series
User Manual V 1.0

81

Virtual COM application in SE5416A Series.

Scroll to the bottom of the page and

click on “Save Configuration” button to save the

changes.

Configure Virtual COM in the Operating System. For Windows, refer to

Chapter 8

. For

Linux, refer to a separate manual included in the Linux driver zip file. Remember the

Destination Port here in order to enter this information in Serial/IP Virtual COM’s Control

Panel later.

7.2.4 TCP Client Application: Enable RFC 2217

The underlying protocol of Virtual COM is based on RFC 2217, the Telnet COM Control Option.

Therefore, it is possible to use RFC 2217 with SE5416A Series in the TCP Client mode. To do

so, refer to

Sec. 7.2.3

to enable Virtual COM, so that SE5416A Series becomes aware of the

commands. Note that there is no need to configure Virtual COM on the Operating System

because Virtual COM ports would not be used.

7.2.5 TCP Server Application: Configure SE5416A Series as a Pair

Connection Master

Pair Connection is useful when pairing up two serial devices over the Ethernet or when it is

impossible to install Virtual COM in the serial device. Pair connection does require two

SE5416A Series to work in pair, one would be the Pair Connection Master and the other would

be the Pair Connection Slave.