ADDRESS LIST

Modbus Programming Manual

17

Version 2

Copyright © 2012 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any means
including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and retrieval systems without
the written permission of Despatch Industries, unless for purchaser's personal use.

Parameter
Name

Modbus
Address
(Dec)

Modbus
Address
(Hex)

Access
R/W

Notes

3

Alarm 1 or Alarm 2 or Alarm 3 or
Alarm 4 or Alarm 5

Event Alarm
Selection

2150

0x0866

R/W

Value

Selection

0

Alarm 1 or Event 1

1

Alarm 2 or Event 2

2

Alarm 3 or Event 3

3

Alarm 4 or Event 4

4

Alarm 5 or Event 5



2.2.2. Relay Output 2 Parameters

Parameter
Name

Modbus
Address
(Dec)

Modbus
Address
(Hex)

Access
R/W

Notes

Usage

2176

0x0880

R/W

Value

Usage

0

None

1

Alarm 1

2

Alarm 2

3

Alarm 3

4

Alarm 4

5

Alarm 5

6

Event 1

7

Event 2

8

Event 3

9

Event 4

10

Event 5

11

Cycle Complete

12

Profile Running

13

Or of Alarms

14

Alarm and Events

Alarm Selection

2178

0x0882

R/W

Value

Selection

0

Alarm 1 or Alarm 2

1

Alarm 1 or Alarm 2 or Alarm 3

2

Alarm 1 or Alarm 2 or Alarm 3 or
Alarm 4

3

Alarm 1 or Alarm 2 or Alarm 3 or
Alarm 4 or Alarm 5

Event Alarm
Selection

2180

0x0884

R/W

Value

Selection

0

Alarm 1 or Event 1

1

Alarm 2 or Event 2

2

Alarm 3 or Event 3

3

Alarm 4 or Event 4

4

Alarm 5 or Event 5